UL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODM

Product Details
Customization: Available
Application: Industrial
Number of Stator: Three-Phase
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (9)
  • UL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODM
  • UL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODM
  • UL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODM
  • UL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODM
  • UL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODM
  • UL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODM
Find Similar Products
  • Overview
  • Product Description
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
NEXP
Function
Driving
Casing Protection
Explosion-Proof Type
Starting Mode
Auto-induction Voltage-reduced Starting
Certification
CCC
Brand
Wolong
Transport Package
Wooden Box
Trademark
WOLONG
Origin
China
HS Code
8501610000

Packaging & Delivery

Package Size
40.00cm * 27.00cm * 25.00cm
Package Gross Weight
30.000kg

Product Description

Product Description

 

NEXP SERIES EXPLOSION-PROOF PREMIUM EFFICIENCY THREE PHASE INDUCTION MOTOR (FRAME143-449)
Technical Agreement
 
  1. General
This meticulous technical agreement is crafted between Nanyang and WWE to effectively carry out the Purchase Order (PO) execution with precision. This agreement should be adhered to strictly unless otherwise specified clearly on the PO.
 
2. Ratings
Table 1 presents the direct correlation between output and frame size
 
HP 3600 (60Hz)
3000(50Hz)
RPM
1800(60Hz)
1500(50Hz)
RPM
1200 (60Hz)
 1000(50Hz)
RPM
1   143T 145T
1.5 143T 145T 182T
2 145T 145T 184T
3 182T 182T 213T
5 184T 184T 215T
7.5 213T 213T 254T
10 215T 215T 256T
15 254T 254T 284T
20 256T 256T 286T
25 284TS 284TS/T 324T
30 286TS 286TS/T 326T
40 324TS 324TS/T 364T
50 326TS 326TS/T 365T
60 364TS 364TS/T 404T
75 365TS 365TS/T 405T
100 405TS 405TS/T 444T
125 444TS 444TS/T 445T
150 445TS 445TS/T 447T
200 447TS 447TS/T 449T
250 449TS 449TS/T  
 
3. Standard Features
Item NEXP Series
Power 1-250HP
Poles 2, 4, 6
Certificate UL certificate E228654;
CSA certificate 1224673;
Altitude 3300ft
Ambient temp. 55ºC: service factor 1.15 with temp. rise within class F (115ºC)
Balancing and Vibration G1.0
Standard: 0. 060 in/sec (p)
Bearing cover 140-210: sealed bearings
250-449: open bearing, both sides fitted with outer and inner covers.
 
Temp. rise for bearing housing 60ºC
 
Bearing protection Labyrinth seal structure
Bearing type Cylindrical bearings for 150-200HP 6 pole motors; Ball bearings for other motors.
Centered core F1-F2 changeable at site
Drain plug No drain plug
Efficiency NEMA Premium Efficiency
End cover End cover material : cast iron HT250
Fan Plastic or cast aluminum
Fan cover Standard material: steel plate, Cast iron for severe environment
Fan cover shape: coned
Fastener Grade 8.8 (equivalent to SAE  grade 5 )
Foot flatness Normal flatness: 0.25mm
Frame material Cast iron
Frame size 143-449
Frequency 60Hz 460V; 50Hz 380V
Lubricating grease Mobil Polyrex EM-2
Earthing All motors have earthing screw inside terminal box.
250-449: earthing screw at frame feet.
Industrial standard Primer: red iron primer; no Intermediate; Finish: polyurethane coating
Insulation class Insulation class F
Insulation system CNE155
The insulation system can meet the requirement of NEMA MG1-31 frequency conversion duty.
Inverter duty CT:5:1; VT:10:1
L10 Bearing service life 130000 hours for direct drive;
26280 hours for belt drive; L10a 50000
Lifting solution 1 off lifting lug with inch thread per motor
Mounting solution F1-F2 changeable to each other.
Installation hole
 
4 holes in each foot
Note: Only 2 holes are for installation. We set 4 holes in case of double frame sizes installation and conversion from F1 to F2.
NEMA Design B
Lubrication 250-449:re-lubricated structure,
One lubricating nipple on end cover at DE , the other on oil pipe at NDE
Rotor Cast Aluminum
Service factor
 
1.15
1.0 when operated on a VFD.
Temperature control Thermostat Harper 7/2/15, please confirm normally closed type, indicate in this spec as well.
Test IEEE 112 B or CSA C390
Service duty S1
Nameplate See clause 4
Packing Wooden (details to be discussed). Suitable for fork from 2 directions for frame 447/9.
Warranty Three years.
 
4. Name Plate Information (Typical)
CAT.NO. NEXP FRAME 449T PHASE 3
DE BRG 6318-C3 ODE BRG 6314-C3 SER. 15F4Y02AW000-01
MAX.AMB. 55ºC INS.CLASS F RATING CONT WEIGHT 1152KG
60Hz HP 250 RPM 1790 HP 200 RPM 1488 50Hz
VOLTS 460 VOLTS 380 415  
F.L.AMPS 284 F.L.AMPS 275 225  
CONN. CODE     G CONN.  
S.F 1.15 DESIGN   B S.F 1.15 DESIGN B CODE J
NEMA NOM.EFF.   96.20% P.F. 0.855 NEMA NOM.EFF. 96.0% P.F. 0.85
NEMA MIN.EFF.           95.40% NEMA MIN.EFF.        95.2%
MAX.KVAR 56    
INVERTER RATED  PWM VFD - 10:1VT, 5:1 CT ,1.0SF
Note: Greg Harper dated 7/2/15:
The nameplate example does not encompass the actual explosion-proof rating such as Class I, Division I, etc.
During the EASA meeting, I conversed with Mr. Liu regarding the necessity for varied temperature codes at distinct ambient temperatures. A copy of the HHI nameplate was also dispatched as a reference. It appears to be the former nameplate. Kindly resubmit the corrected version.
 
5. Electrical Performances

Table 2: Performance Metrics assessed at 460V 60Hz
 
HP Full
Load
RPM
Current (A) KVAR CODE Rotor Inertia
(kg.m)
Efficiency (%) Power
Factor
(%)
LRT
(%)
BDT
(%)
FLA LRA 1/2 load 3/4 load Full load
Nom. Min.
1 1773 1.35 15 N 0.0067 81.3 84.5 85.5 82.5 78.5 311 412
1 1175 1.65 15 N 0.0081 78.0 81.0 82.5 80.0 66.0 342 341
1.5 3511 1.85 20 M 0.0026 83.5 85.1 84.0 81.5 84.5 289 378
1.5 1769 1.95 20 M 0.0091 83.0 86.0 86.5 84.0 79.0 291 377
1.5 1183 2.07 20 M 0.011 84.5 87 87.5 85.5 71.0 239 341
2 3504 2.5 25 L 0.0035 85.3 86.0 85.5 82.5 86.0 219 252
2 1765 2.6 25 L 0.017 84.0 86.0 86.5 84.0 83.7 250 298
2 1183 2.8 25 L 0.018 86.0 88.0 88.5 86.5 73.0 249 324
3 3528 3.5 32 K 0.0089 85.5 87.0 86.5 84.0 87.0 187 307
3 1761 3.8 32 K 0.019 87.5 89.0 89.5 87.5 77.0 232 322
3 1182 3.95 32 K 0.035 87.5 89.0 89.5 87.5 71.0 295 349
5 3525 6 46 J 0.015 85.0 87.0 88.5 86.5 85.0 177 306
5 1756 7 46 J 0.028 87.0 89.2 89.5 87.5 81.0 187 265
5 1178 7.5 46 J 0.04 85.0 89.5 89.5 87.5 75.0 222 275
7.5 3539 8.3 63.5 H 0.033 85.0 90.0 89.5 87.5 86.0 181 262
7.5 1773 8.9 63.5 H 0.036 89.0 91.5 91.7 90.2 84.0 239 302
7.5 1186 12.5 63.5 H 0.06 89.0 91.0 91.0 89.5 78.0 206 289
10 3540 11.5 81 H 0.038 89.0 90.2 90.2 88.5 88.0 183 264
10 1772 12.2 81 H 0.073 90.0 92.0 91.7 90.2 82.0 251 266
10 1178 12.5 81 H 0.065 89.0 90.0 91.0 89.5 81.0 204 289
15
15
15
3538
1767
1181
16.5
17.5
18.1
116
116
145
G
G
G
0.058
0.097
0.16
89.0
89.0
90.0
90.0
90.0
92.0
91.0
92.4
91.7
89.5
91.0
90.2
86.0
87.0
82.0
221
196
210
268
267
248
20
20
20
3531
1777
1179
22.8
23
23.5
145
145
145
G
G
G
0.065
0.18
0.20
88.0
90.0
89.0
90.0
92.0
91.5
91.0
93.0
91.7
89.5
91.7
90.2
88.0
87.0
81.0
206
193
15 5
245
248
240
 
HP Full
Load
RPM
Current (A)
KVAR
CODE
Rotor Inertia
(kg.m)
Efficiency (%) Power
Factor (%)
LRT
(%)
BDT
(%)
FLA LRA 1/2 load 3/4 load Full load
Nom. Min.
25 3560 27.5 182.5 G 0.082 91.5 91.9 91.7 90.2 88.0 170 261
25 1778 27.5 182.5 G 0.24 93.1 93.6 93.6 92.4 85.0 171 251
25 1187 29.0 182.5 G 0.28 92.8 93.2 93.0 91.7 83.0 180 250
30 3560 32.5 217.5 G 0.098 91.5 91.9 91.7 90.2 89.0 179 265
30 1777 32.5 217.5 G 0.40 93.1 93.7 93.6 92.4 87.0 172 251
30 1187 37.1 217.5 G 0.33 92.8 93.2 93.0 91.7 78.0 158 238
40 3566 44.5 290.0 G 0.15 91.8 92.4 92.4 91.0 88.0 169 238
40 1783 46.0 290.0 G 0.46 93.9 94.2 94.1 93.0 85.0 186 252
40 1188 47.5 290.0 G 0.57 93.9 94.3 94.1 93.0 83.0 219 264
50 3573 54.0 362.5 G 0.18 92.4 93.0 93.0 91.7 88.0 184 243
50 1783 55.0 362.5 G 0.77 94.2 94.6 94.5 93.6 85.0 173 263
50 1188 56.5 362.5 G 0.65 93.9 94.3 94.1 93.0 83.0 209 256
60 3573 68.0 435.0 G 0.32 93.1 93.6 93.6 92.4 88.0 159 267
60 1786 70.0 435.0 G 0.87 94.2 94.9 95.0 94.1 85.0 195 270
60 1192 69.0 435.0 G 1.1 94.1 94.5 94.5 93.6 83.0 187 234
75 3573 84.5 542.5 G 0.36 93.2 93.6 93.6 92.4 88.0 172 277
75 1786 86.5 542.5 G 1.1 94.5 95.3 95.4 94.5 85.0 211 275
75 1192 89.0 542.5 G 1.3 94.2 94.6 94.5 93.6 83.0 197 251
100 3579 110.0 725.0 G 0.55 93.7 94.1 94.1 93.0 89.0 159 279
100 1790 112.0 725.0 G 1.4 94.8 95.4 95.4 94.5 87.0 199 247
100 1190 117.0 725.0 G 2.4 94.7 95.1 95.0 94.1 84.0 152 241
125 3586 130.0 907.5 G 0.79 94.2 94.8 95.0 94.1 89.0 153 268
125 1789 133.0 907.5 G 2.4 94.8 95.4 95.4 94.5 85.0 188 271
125 1191 135.0 907.5 G 2.9 94.7 95.1 95.0 94.1 84.0 148 246
150 3585 160.0 1085.0 G 0.97 94.4 94.9 95.0 94.1 87.0 150 256
150 1789 162.5 1085.0 G 2.9 95.7 95.8 95.8 95.0 86.0 164 262
150 1191 166.0 1085.0 G 3.5 95.3 95.8 95.8 95.0 82.0 210 252
200 3584 213.5 1450.0 G 1.3 95.0 95.4 95.4 94.5 87.0 168 264
200 1789 223.0 1450.0 G 3.5 95.8 96.2 96.2 95.4 85.0 187 275
200 1191 227.5 1450.0 G 4.3 95.5 95.9 95.8 95.0 82.0 157 263
250 3585 262.0 1825.0 G 1.6 95.3 95.7 95.8 95.0 87.0 200 280
250 1788 268.0 1825.0 G 4.3 96.0 96.3 96.2 95.4 85.0 228 244
250 1191 280.0 1825.0 G --- 95.5 95.9 95.8 95.0 82.0 185 250
  1. Mounting & Overall Dimensions
Table 3 offers Dimensions for Foot-Mounted Motors with Single Straight-Shaft Extension(Inch)
Harper 7/2/15- Table 3 is missing; please insert and resubmit. The C dimension is necessary to verify the usability of the 'cone' shaped fan cover.
UL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODM

Table 4 Dimensions for C Face-Mounted or Footless Motors (Inch)
 

Frame Size

AJ

AK

BA*

BB Min

BC

BD Max
BF Hole
U

AH
Keyway
Number Tap Size Bolt
Penetration Allowance
R ES Min
S
 
143TC  145TC 5.88 4.5 2.25* 0.16 +0.12 6.5 4 3/8-16 0.56 0.875 2.12 0.771 1.41 0.188
182TC  184TC 7.25 8.5 2.75* 0.25 +0.12 9 4 1/2-13 0.75 1.125 2.62 0.986 1.78 0.25
213TC  215TC 7.25 8.5 3.5* 0.25 +0.25 9 4 1/2-13 0.75 1.375 3.12 1.201 2.41 0.312
254TC  256TC 7.25 8.5 4.25* 0.25 +0.25 10 4 1/2-13 0.75 1.625 3.75 1.416 2.91 0.375
284TC   286TC 9 10.5 4.75 0.25 +0.25 11.25 4 1/2-13 0.75 1.875 4.38 1.591 3.28 0.500
284TSC  286TSC 9 10.5 4.75 0.25 +0.25 11.25 4 1/2-13 0.75 1.625 3.00 1.416 1.91 0.375
324TC   326TC 11 12.5 5.25 0.25 +0.25 14 4 5/8-11 0.94 2.125 5.00 1.845 3.91 0.500
324TSC  326TSC 11 12.5 5.25 0.25 +0.25 14 4 5/8-11 0.94 1.875 3.50 1.591 2.03 0.500
364TC   365TC 11 12.5 5.88 0.25 +0.25 14 8 5/8-11 0.94 2.375 5.62 2.021 4.28 0.625
364TSC  365TSC 11 12.5 5.88 0.25 +0.25 14 8 5/8-11 0.94 1.875 3.50 1.591 2.03 0.500
404TC   405TC 11 12.5 6.62 0.25 +0.25 15.5 8 5/8-11 0.94 2.875 7.00 2.450 5.65 0.750
404TSC  405TSC 11 12.5 6.62 0.25 +0.25 15.5 8 5/8-11 0.94 2.125 4.00 1.845 2.78 0.500
444TC   445TC 14 16 7.5 0.25 +0.25 18 8 5/8-11 0.94 3.375 8.25 2.880 6.91 0.875
444TSC  445TSC 14 16 7.5 0.25 +0.25 18 8 5/8-11 0.94 2.375 4.50 2.021 3.03 0.625
447TC   449TC 14 16 7.5 0.25 +0.25 18 8 5/8-11 0.94 3.375 8.25 2.880 6.91 0.875
447TSC  449TSC 14 16 7.5 0.25 +0.25 18 8 5/8-11 0.94 2.375 4.50 2.021 3.03 0.625
* For frames 143TC-256TC, dimension BA differs from NEMA MG1 4.4.4, ensuring interchangeability from a TC flange to a T flange.

UL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODM
Certifications

UL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODMUL Nexp Series High-Efficiency Explosion-Proof Electric Motor for Three Phase Applications OEM/ODM

FAQ

Q1: Is customized service available?

A1: Of course, OEM & ODM both are available.


Q2:Can I buy one as sample?

A2: Yes, of course.



Q3: How about your quality control?

A3: Our professional QC will check the quality during the production and do the quality test before shipment.

Q4: What is your payment term?

A4: 30% T/T in advance, 70% balance when receiving B/L copy Or 100% irrevocable L/C at sight.


Q5: What is your lead time?

A5: About 20-30 days after receiving advance deposit or original L/C.


Q6 What certificates do you have?

A6: We have CE, ISO. And we can apply for specific certificate for different country such as SONCAP for Nigeria, COI for Iran, SASO for Saudi Arabia, etc.


Q7: What warranty do you provide?

A7: One year, during the guarantee period, we will supply freely of the easy damaged parts for the possible problems except for the incorrect operation. After expiration, we supply cost spare parts for alternator maintenance.
Q1: Is customized service available?

A1: Of course, OEM & ODM both are available.


Q2:Can I buy one as sample?

A2: Yes, of course.



Q3: How about your quality control?

A3: Our professional QC will check the quality during the production and do the quality test before shipment.

Q4: What is your payment term?

A4: 30% T/T in advance, 70% balance when receiving B/L copy Or 100% irrevocable L/C at sight.


Q5: What is your lead time?

A5: About 20-30 days after receiving advance deposit or original L/C.


Q6 What certificates do you have?

A6: We have CE, ISO. And we can apply for specific certificate for different country such as SONCAP for Nigeria, COI for Iran, SASO for Saudi Arabia, etc.


Q7: What warranty do you provide?

A7: One year, during the guarantee period, we will supply freely of the easy damaged parts for the possible problems except for the incorrect operation. After expiration, we supply cost spare parts for alternator maintenance.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier